The Set-up is designed to study the performance of Reciprocating Pump. The Set up consists of a Reciprocating Pump coupled with electrical motor, supply tank, measuring tank & pipe fittings for closed loop water circulation. Pressure and Vacuum Gauge are connected on delivery and suction side of pump for the purpose of measurement. The flow rate of water is measured using measuring tank and stop watch provided.
EXPERIMENT
To determine overall efficiency and pump efficiency of the Reciprocating Pump
To plot Head Vs. Discharge, Pump efficiency Vs. Discharge
FEATURES
Closed loop water circulation
Compact & stand alone set·up
MS Excel sample calculation program on demand
Stainless Steel tanks and wetted parts
Superb painted structure
Simple to Operate & Maintain
Salient Features
Pump : Double acting, single Cylinder, Capacity 1 HP Speed 250 RPM (max), Head 5kg/cm2(max.)
Drive : AC Motor with HP cone pulley arrangement for 3 prefixed speed Or DC Motor with DC Drive along with non contact type Digital RPM indicator.
Supply Tank : Capacity 70 ltr.
Measuring Tank : Capacity 50 Ltrs. fitted with Piezometer Tube & Scale
Piping : GI/PVC
Stop Watch : Electronic
Control Panel : With required electrical instrumentation.
The whole Set-up is well designed and arranged in a good quality painted structure.