Double Beam UV-VIS Spectrophotometer with Software
- Wavelength Range: 190-1100 nm
- Optical System: Double Beam
- Spectral Bandwidth: 1 nm
- Model No / Item Code: IMS-01
- Grating: 1200 lines / mm
- Data Output Port: USB Port
- Display: 5 inches graphic LCD
- Sample Compartment: 8 position auto cell changer
- Printer Port: Parallel Port
Double Beam UV-VIS Spectrophotometer with Software - (IMS-01)Micro controller Based Instrument having range 190-1100 nm, On-screen standard curve display on large 5 inches graphic LCD, 1.0 nm Spectral Bandwidth, 1200 Lines/mm Grating, 8 position auto cell changer, Wavelength Scanning, PC connectivity through USB port & direct printer connectivity using parallel port interface. It has facility for WL Scan, Kinetics, Multi Wavelength & DNA/Protein modes,inclusive of PC software.
Salient Features- Accessories on Request
- 80 character centronics dot matrix printer
- Quartz cuvettes 10mm path length(set of 2)
- Glass cuvettes 10mm path length(set of 2)
- Set of 2 Glass Cuvettes(50mm path length)
- Spare lamp(Vis.) Halogen 6V 10W
- Polystyrene cuvettes 10mm path length (set of 5)
Double Beam UV/VIS Spectrophotometer
- Wavelength Range: 190-1100 nm
- Optical System: Double Beam
- Model No / Item Code: IMS-02
- Data Output Port: USB Port
- Display: 24 x 2 line LCD display
- Sample Compartment: 2 Quartz & Set of 4 Glass Cuvettes
Micro controller Based instrument having range 190 to 1100 nm with 24 x 2 line LCD display, two quartz cuvettes, 18 touch keys, base line correction, source optimization & electronic calibration etc. It has facility for measurement of %T, Abs. Conc., K-Factor and multi component analysis. A set of 2 Quartz & Set of 4 Glass Cuvettes. The operating modes are single/multi-wave length, wavelength scan,time scan etc. PC Software at extra cost
Salient Features- Accessories on Request
- RS-232 Computer Software
- 80 character centronics dot matrix printer
- Quartz cuvettes 10mm path length(set of 2)
- Glass cuvettes 10mm path length(set of 2)
- Set of 2 Glass Cuvettes(50mm path length)
- Spare lamp(Vis.) Halogen 6V 10W
- Polystyrene cuvettes 10mm path length (set of 5)
Digital UV-VIS Spectrophotometer
- Wavelength Range: 190-1000 nm
- Optical System: Single Beam
- Model No / Item Code: IMS-04
- Data Output Port: USB Port
- Display: 31/2 digit LED data display
- Sample Compartment: 4 position sample holder with position selector control for 10 mm path length cuvettes
Range 190 to 1000 nm with facility for automatic Concentration, %T & Absorbance measurements. Motorized Micro controller based Wavelength Selection, 4 digit LED display for Wavelength, 3½ digit LED data display. It has 4 position sample holder with position selector control for 10 mm path length cuvettes. A set of 2 quartz cuvettes is provided.
Salient Features- Accessories on Request
- RS-232 Computer Software
- 80 character centronics dot matrix printer
- Quartz cuvettes 10mm path length(set of 2)
- Glass cuvettes 10mm path length(set of 2)
- Set of 2 Glass Cuvettes(50mm path length)
- Spare lamp(Vis.) Halogen 6V 10W
- Polystyrene cuvettes 10mm path length (set of 5)
Microprocessor Visible Spectrophotometer (Scanning)
- Wavelength Range: 320-1100nm
- Model No / Item Code: IMS-05
- Data Output Port: USB [port & direct printer connectivity using parallel port interface]
- Display: Graphic LCD
- Usage / Application: Lab Use
- Wavelength resolution: 0.1 nm
Microprocessor Visible Spectrophotometer (Scanning) - (IMS-05)
Range 320-1100 nm. On-screen standard curve display on Graphic LCD, PC connectivity through USB [port & direct printer connectivity using parallel port interface, Auto zero and blank. 0.1 nm wavelength Scanning can be done using professional PC Software
Salient Features- Accessories on Request
- RS-232 Computer Software
- 80 character centronics dot matrix printer
- Quartz cuvettes 10mm path length(set of 2)
- Glass cuvettes 10 mm path length(set of 2)
- Set of 2 Glass Cuvettes(50 mm path length)
- Spare lamp(Vis.) Halogen 6V 10W
- Polystyrene cuvettes 10 mm path length (set of 5)
Single Beam UV-VIS Spectrophotometer
- Wavelength Range: 190-1100 nm
- Optical System: Single Beam
- Model No / Item Code: IMS-03
- Data Output Port: USB Port
- Display: 16 x 2 line LCD data display
- Sample Compartment: quad sample holder with 4 position selector control
- Data Storage: 100 sample data storage
- Printer Port: Parallel Port
Micro controller Based instrument having range 190 to 1100nm with basic PC software and 4 position cell changer. It has graphic LCD for display of kinetic,concentration graphs. PC connectivity through USB Port & direct printer connectivity using parallel port interface. Extensive elaborate keyboard for ease of operator. Sample compartment can accommodate upto 100mm cuvettes(optional). Basic modes like %T,Abs, Concentration, Kinetics available. Wavelength Scanning and DNA/Proteins can be done using advanced professional PC Software Models Available are -
- It has 16 x 2 line LCD data display and motorized wavelength selection on 4 digit LED display. It has quad sample holder with 4 position selector control for 10 mm path length cuvettes. Facility has been provided for 100 sample data storage and interface with any centronic printer.
Salient Features- Accessories on Request
- RS-232 Computer Software
- 80 character centronics dot matrix printer
- Quartz cuvettes 10mm path length(set of 2)
- Glass cuvettes 10mm path length(set of 2)
- Set of 2 Glass Cuvettes(50mm path length)
- Spare lamp(Vis.) Halogen 6V 10W
- Polystyrene cuvettes 10mm path length (set of 5)
Microprocessor Visible Spectrophotometer
- Wavelength Range: 325-1000 nm
- Model No / Item Code: IMS-06
- Data Output Port: USB port & direct printer connectivity using parallel port interface
- Display: 4 digit Large LED display
- Usage / Application: Lab Use
- Wavelength resolution: 2 nm
Range 325-1000nm. 4 digit Large LED display, PC connectivity through USB port & direct printer connectivity using parallel port interface, Auto zero and blank, 2nm wavelength resolution, with basic PC software
Salient Features- Accessories on Request
- RS-232 Computer Software
- 80 character centronics dot matrix printer
- Quartz cuvettes 10mm path length(set of 2)
- Glass cuvettes 10 mm path length(set of 2)
- Set of 2 Glass Cuvettes(50 mm path length)
- Spare lamp(Vis.) Halogen 6V 10W
- Polystyrene cuvettes 10 mm path length (set of 5)
Digital Spectrophotometer
- Wavelength Range: 340-960 nm
- Model No / Item Code: IMS-07
- Lamp Type: Tungsten Halogen Lamp
- Data Output Port: RS 232C
- Display: 31/2 LED display
- Sample Compartment: 10 mm & 50 mm cuvettes holders with adapter is available
- Printer Port: Dot matrix printer for centronics interface
Range 340–960 nm with facility for automatic concentration, %Transmission & Absorbance measurement. Simultaneous display of wave length with 1nm resolution on 3 digit LED display and data on a 3½ LED display are available. Provision for 10 mm & 50 mm cuvettes holders with adapter is available. A set of 10 mm path length glass cuvette is supplied with the instrument. 50mm cuvette set can be provided at extra cost.
Salient Features- Accessories on Request
- Set of 2 Glass cuvettes(10 mm Path length)
- Set of 2 Quartz cuvettes(10 mm Path length)
- Set of 2 Glass cuvettes(50 mm Path length)
- Set of Round glass test tube 10 mm path length
- Spare lamp 6v, 10W (Tungsten Halogen lamp)
- Polystyrene Cuvettes 10 mm path length (a set of 5)
- Dot matrix printer for centronics interface
- RS 232C software